Anton Paar TAG Flash Point Tester - TAG ...
TAG 500 and TAG 300: Our next-generation closed-cup TAG flash point tester series. Guided flash point measurements (acc. to ASTM D56, ASTM D3941, ASTM D3934, ISO 1516, ISO 1523, etc). For jet fuels, solvents, flavors and fragrances, chemicals, and other flammable liquids. Automatic. High-precision. -35 °C to +130 °C sample temperature range. Components with the longest lifetime on the market.
Our TAG flash point testers: Deftly engineered, highly precise, reliable, and supremely robust:
TAG 500 features a groundbreaking cooling system combination for Tagliabue flash point testing:
TAG 300 has a budget-friendly, straightforward internal cooling system that allows measurements with flash points between +10 °C and +110 °C.
TAG 500 protects your staff and lab:
TAG 300 can optionally be upgraded with a fire extinguisher and unique fire detection system.
TAG 300 | TAG 500 | |
Test methods | ASTM D56 Equilibrium procedures: ASTM D3941, ASTM D3934, ISO 1516, ISO 1523 >1,000 user-defined test programs |
|
Application range (flash point temperature) | +10 °C to +110 °C | Internal cooling +10 °C to +130 °C External cooling -30 °C to +130 °C |
Sample temperature range | -7 °C to +110 °C | Internal cooling -7 °C to 130 °C External cooling -35 °C to +130 °C |
Ignition type | Electric (encapsulated hot wire) | Electric (encapsulated hot wire) Optional gas ignition |
Heating rate | According to standard or user-defined | |
Cooling | Fan-supported internal Peltier cooling technology | Fan-supported internal Peltier cooling technology or external cooler |
Barometric pressure correction | Flash point is automatically corrected to barometric pressure | |
Flash detection | Automatic detection by thermocouple | |
Sample temperature | Measured by Pt100 | |
Safety | Overheat protection, automatic shut-off | Detects a “flash” outside the cup Optional automatic fire-extinguishing system in combination with a unique optical fire detection system User management with different access levels |
Overheat protection, automatic shut-off | Detects a “flash” outside the cup Automatic fire-extinguishing system in combination with a unique optical fire detection system as standard User management with different access levels |
Calibration | Calibration of sample and block temperature, and internal barometer | |
Handling | TFT touchscreen | Small footprint | Manual lifting/lowering of multi-function head | No open cables | User-definable measurement parameters and units | Display of test progress in real time |
TFT touchscreen | Small footprint | Fully automatic multi-function head | No open cables | User-definable measurement parameters and units | Display of test progress in real time |
Memory | 1 GB space for approx. 50,000 tests and 1,000 users | |
Statistics | Mean, min, max, repeatability, standard deviation, max. deviation | |
Interfaces | 2 × USB, 1 × LAN | 4 × USB, 1 × LAN |
Input options | Optional USB keyboard/mouse/barcode reader | |
Display | 7" TFT, PCAP touchscreen | |
Power supply | 100 V to 240 V, 50/60 Hz, 300 W | |
Gas supply | Optional fire extinguisher: CO2 or N2 inert gas; inlet pressure 400 kPa to 500 kPa | Integrated fire extinguisher: CO2 or N2 inert gas; inlet pressure 400 kPa to 500 kPa Optional gas ignition: 50 mbar of propane or butane |
Dimensions | 262 mm × 472 mm × 437 mm (W × D × H) | 262 mm × 497 mm × 477 mm (W × D × H) |
Weight | Ca. 14 kg | Ca. 15 kg |
Options | Standard test insert in brass or stainless steel, calibration set, condensation protection, draft shield Fire extinguisher |
Standard test insert in brass or stainless steel, calibration set, condensation protection, draft shield Gas igniter |
To contact Anton Paar Australia about Anton Paar TAG Flash Point Tester - TAG 300/500 use Get a quote.
TAG 500 and TAG 300: Our next-generation closed-cup TAG flash point tester series. Guided flash point measurements (acc. to ASTM D56, ASTM D3941, ASTM D3934, ISO 1516, ISO 1523, etc). For jet fuels, solvents, flavors and fragrances, chemicals, and other flammable liquids. Automatic. High-precision. -35 °C to +130 °C sample temperature range. Components with the longest lifetime on the market.
Our TAG flash point testers: Deftly engineered, highly precise, reliable, and supremely robust:
TAG 500 features a groundbreaking cooling system combination for Tagliabue flash point testing:
TAG 300 has a budget-friendly, straightforward internal cooling system that allows measurements with flash points between +10 °C and +110 °C.
TAG 500 protects your staff and lab:
TAG 300 can optionally be upgraded with a fire extinguisher and unique fire detection system.
TAG 300 | TAG 500 | |
Test methods | ASTM D56 Equilibrium procedures: ASTM D3941, ASTM D3934, ISO 1516, ISO 1523 >1,000 user-defined test programs |
|
Application range (flash point temperature) | +10 °C to +110 °C | Internal cooling +10 °C to +130 °C External cooling -30 °C to +130 °C |
Sample temperature range | -7 °C to +110 °C | Internal cooling -7 °C to 130 °C External cooling -35 °C to +130 °C |
Ignition type | Electric (encapsulated hot wire) | Electric (encapsulated hot wire) Optional gas ignition |
Heating rate | According to standard or user-defined | |
Cooling | Fan-supported internal Peltier cooling technology | Fan-supported internal Peltier cooling technology or external cooler |
Barometric pressure correction | Flash point is automatically corrected to barometric pressure | |
Flash detection | Automatic detection by thermocouple | |
Sample temperature | Measured by Pt100 | |
Safety | Overheat protection, automatic shut-off | Detects a “flash” outside the cup Optional automatic fire-extinguishing system in combination with a unique optical fire detection system User management with different access levels |
Overheat protection, automatic shut-off | Detects a “flash” outside the cup Automatic fire-extinguishing system in combination with a unique optical fire detection system as standard User management with different access levels |
Calibration | Calibration of sample and block temperature, and internal barometer | |
Handling | TFT touchscreen | Small footprint | Manual lifting/lowering of multi-function head | No open cables | User-definable measurement parameters and units | Display of test progress in real time |
TFT touchscreen | Small footprint | Fully automatic multi-function head | No open cables | User-definable measurement parameters and units | Display of test progress in real time |
Memory | 1 GB space for approx. 50,000 tests and 1,000 users | |
Statistics | Mean, min, max, repeatability, standard deviation, max. deviation | |
Interfaces | 2 × USB, 1 × LAN | 4 × USB, 1 × LAN |
Input options | Optional USB keyboard/mouse/barcode reader | |
Display | 7" TFT, PCAP touchscreen | |
Power supply | 100 V to 240 V, 50/60 Hz, 300 W | |
Gas supply | Optional fire extinguisher: CO2 or N2 inert gas; inlet pressure 400 kPa to 500 kPa | Integrated fire extinguisher: CO2 or N2 inert gas; inlet pressure 400 kPa to 500 kPa Optional gas ignition: 50 mbar of propane or butane |
Dimensions | 262 mm × 472 mm × 437 mm (W × D × H) | 262 mm × 497 mm × 477 mm (W × D × H) |
Weight | Ca. 14 kg | Ca. 15 kg |
Options | Standard test insert in brass or stainless steel, calibration set, condensation protection, draft shield Fire extinguisher |
Standard test insert in brass or stainless steel, calibration set, condensation protection, draft shield Gas igniter |
To contact Anton Paar Australia about Anton Paar TAG Flash Point Tester - TAG 300/500 use Get a quote.