Anton Paar Total Package Oxygen Meter | ...
Combined TPO and CO2 measurement
Measuring range | Trace range sensor | Wide range sensor |
Oxygen in the gas phase | 0 hPa to 45 hPa | 0 hPa to 1000 hPa |
Dissolved oxygen | 0 ppm to 2 ppm | 0 ppm to 45 ppm |
Temperature[1] | 0 °C to 40 °C (32 °F to 104 °F) for non-frozen samples | |
Pressure | 5 to 6.2 bar abs. | |
Repeatability | ||
TPO[2] | ± 8 ppb or ± 6%, whichever is higher | ± 25 ppb or ± 6%, whichever is higher |
Environmental conditions | ||
Ambient temperature | 15 °C to 35 °C (50 to 95 °F), 0 °C to 40 °C (32 °F to 104 °F) on request | |
Relative humidity (non-condensing)[3] | 10 % to 90 % | |
Package dimensions | ||
Package diameter | 35 mm to 90 mm (1.4 in to 3.5 in) | |
Package height | 30 mm to 370 mm (1.2 in to 14.6 in) | |
Package volume[4] | 150 mL to 2000 mL | |
Tested packages and sample types[5] | ||
Glass (without cork) | 12 oz, 14.5 oz, 18 oz, 22 oz, 22.4 oz, 24 oz, 32 oz, 40 oz; 250 mL, 330 mL, 750 mL, 1000 mL | |
PET | 42 oz; 1000 mL | |
Aluminum bottle | 14 oz, 2000 mL | |
Aluminum can | 8 oz, 10 oz, 12 oz, 16 oz, 25 oz; 330 mL, 500 mL | |
Typical sample types | All common styles of beer, selzer, water, cola. All non-pulp containing. | |
Further details | ||
Gas consumption / measurement | Vn= 8 L | |
Required oxygen-free gases | N2 or CO2 class 5 (if TPO 5000 is used without CO2 measurement) 5 bar to 6.2 bar abs. non-fluctuating (± 0.1 bar) | |
Additional gases[6] | Compressed air 5 to 6.5 bar abs., oil free | |
Cleaning | Tap water or process water (chlorine-free) 1.5 bar to 4.5 bar abs.; periodically special cleaning is necessary | |
Communication interfaces | 3x USB, Ethernet, CAN (for Anton Paar devices only), RS232 | |
Power supply | AC 85 V to 264 V, 45 Hz to 66 Hz or DC 88 V to 370 V | |
Display | 7'' LCD panel touch screen | |
Data storage | Up to 5000 measurement data sets | |
Degree of protection | IPX3 | |
Dimensions (L x W x H) | 515 mm x 590 mm x 1120 mm (20.3 in x 44.1 in) | |
Weight | 70 kg (154 lbs) | |
Altitude | Max. 2000 m |
[1] 35 °C (95 °F) for carbonization levels >5.5 g/L, 10 °C (50 °F) for carbonization levels >10 g/L.
[2] At ambient and sample temperature of 23 °C (73.4 °F) and if standard cleaning is applied. Please note, that the first measurement of a set is not considered for the determination of the repeatibility of the set.
[3] Purging the instrument with dry air is required at high relative humidity.
[4] For TPO only, >300 mL for TPO and CarboQC.
[5] Approval for other package types on request. Approval for other sample types on request.
[6] Oxygen-free gas can be used if no compressed air connection is available.
To contact Anton Paar Australia about Anton Paar Total Package Oxygen Meter | TPO 5000 use Get a quote.
Combined TPO and CO2 measurement
Measuring range | Trace range sensor | Wide range sensor |
Oxygen in the gas phase | 0 hPa to 45 hPa | 0 hPa to 1000 hPa |
Dissolved oxygen | 0 ppm to 2 ppm | 0 ppm to 45 ppm |
Temperature[1] | 0 °C to 40 °C (32 °F to 104 °F) for non-frozen samples | |
Pressure | 5 to 6.2 bar abs. | |
Repeatability | ||
TPO[2] | ± 8 ppb or ± 6%, whichever is higher | ± 25 ppb or ± 6%, whichever is higher |
Environmental conditions | ||
Ambient temperature | 15 °C to 35 °C (50 to 95 °F), 0 °C to 40 °C (32 °F to 104 °F) on request | |
Relative humidity (non-condensing)[3] | 10 % to 90 % | |
Package dimensions | ||
Package diameter | 35 mm to 90 mm (1.4 in to 3.5 in) | |
Package height | 30 mm to 370 mm (1.2 in to 14.6 in) | |
Package volume[4] | 150 mL to 2000 mL | |
Tested packages and sample types[5] | ||
Glass (without cork) | 12 oz, 14.5 oz, 18 oz, 22 oz, 22.4 oz, 24 oz, 32 oz, 40 oz; 250 mL, 330 mL, 750 mL, 1000 mL | |
PET | 42 oz; 1000 mL | |
Aluminum bottle | 14 oz, 2000 mL | |
Aluminum can | 8 oz, 10 oz, 12 oz, 16 oz, 25 oz; 330 mL, 500 mL | |
Typical sample types | All common styles of beer, selzer, water, cola. All non-pulp containing. | |
Further details | ||
Gas consumption / measurement | Vn= 8 L | |
Required oxygen-free gases | N2 or CO2 class 5 (if TPO 5000 is used without CO2 measurement) 5 bar to 6.2 bar abs. non-fluctuating (± 0.1 bar) | |
Additional gases[6] | Compressed air 5 to 6.5 bar abs., oil free | |
Cleaning | Tap water or process water (chlorine-free) 1.5 bar to 4.5 bar abs.; periodically special cleaning is necessary | |
Communication interfaces | 3x USB, Ethernet, CAN (for Anton Paar devices only), RS232 | |
Power supply | AC 85 V to 264 V, 45 Hz to 66 Hz or DC 88 V to 370 V | |
Display | 7'' LCD panel touch screen | |
Data storage | Up to 5000 measurement data sets | |
Degree of protection | IPX3 | |
Dimensions (L x W x H) | 515 mm x 590 mm x 1120 mm (20.3 in x 44.1 in) | |
Weight | 70 kg (154 lbs) | |
Altitude | Max. 2000 m |
[1] 35 °C (95 °F) for carbonization levels >5.5 g/L, 10 °C (50 °F) for carbonization levels >10 g/L.
[2] At ambient and sample temperature of 23 °C (73.4 °F) and if standard cleaning is applied. Please note, that the first measurement of a set is not considered for the determination of the repeatibility of the set.
[3] Purging the instrument with dry air is required at high relative humidity.
[4] For TPO only, >300 mL for TPO and CarboQC.
[5] Approval for other package types on request. Approval for other sample types on request.
[6] Oxygen-free gas can be used if no compressed air connection is available.
To contact Anton Paar Australia about Anton Paar Total Package Oxygen Meter | TPO 5000 use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product