CEM DT-9881 Air Particle Counter + Gas ...
THE CEM DT-9881 Air Particle Counter + Gas Detector provides fast,easy and accurate readings for particle count, GAS Formaldehyde (HCHO) & Carbon Monoxide (CO) detectection, air temperature & relative humidity &,most surface temperature measurements.
It is the ideal instrument for environmental and energy saving surveys.
Particle Counter | |
Channel | 0.3, 0.5, 1.0, 2.5, 5.0, 10μm |
Flow Rate | 0.1ft3(2.83L/min) controlled by internal pump |
Count Modes | Totalize, Concentration, Audio |
Coincidence Loss | 5%, 2000000 particles per ft3 |
IR Temperature Measure | |
IR Temp. Range | -20.0ºC to 500.0ºC Basic Accuracy: ±1.5% of reading |
Optical Resolution | 8:1 Distance to Spot size |
Emissivity Adjustable | 0.10~1.0 Adjustable |
Response Time | 500mS |
Air Temperature Measure | |
Air Temp Range | 0 to 50ºC; Basic Accuracy:±0.5ºC |
Humidity Range | 0 to 100%RH; Basic Accuracy:±2.5%RH(20%~80%RH) |
Dew Point Temp. Range | -30~100ºC |
Wet Bulb Temp. Range | 0~80ºC |
GAS Detectors | |
HCHO Range | 0.01~5.00ppm; Basic Accuracy: ±5%± 0.01ppm |
CO (carbon monoxide) Range | 0~1000ppm; Basic Accuracy:±5% ± 10ppm |
Other | |
Battery | Rechargeable battery(Could be use 4 hours) |
Charging time | 2 hours |
Size | 240*75*57mm |
Weight | 570g |
To contact OBIAT Electronics Pty Ltd about CEM DT-9881 Air Particle Counter + Gas Detector use Get a quote.
THE CEM DT-9881 Air Particle Counter + Gas Detector provides fast,easy and accurate readings for particle count, GAS Formaldehyde (HCHO) & Carbon Monoxide (CO) detectection, air temperature & relative humidity &,most surface temperature measurements.
It is the ideal instrument for environmental and energy saving surveys.
Particle Counter | |
Channel | 0.3, 0.5, 1.0, 2.5, 5.0, 10μm |
Flow Rate | 0.1ft3(2.83L/min) controlled by internal pump |
Count Modes | Totalize, Concentration, Audio |
Coincidence Loss | 5%, 2000000 particles per ft3 |
IR Temperature Measure | |
IR Temp. Range | -20.0ºC to 500.0ºC Basic Accuracy: ±1.5% of reading |
Optical Resolution | 8:1 Distance to Spot size |
Emissivity Adjustable | 0.10~1.0 Adjustable |
Response Time | 500mS |
Air Temperature Measure | |
Air Temp Range | 0 to 50ºC; Basic Accuracy:±0.5ºC |
Humidity Range | 0 to 100%RH; Basic Accuracy:±2.5%RH(20%~80%RH) |
Dew Point Temp. Range | -30~100ºC |
Wet Bulb Temp. Range | 0~80ºC |
GAS Detectors | |
HCHO Range | 0.01~5.00ppm; Basic Accuracy: ±5%± 0.01ppm |
CO (carbon monoxide) Range | 0~1000ppm; Basic Accuracy:±5% ± 10ppm |
Other | |
Battery | Rechargeable battery(Could be use 4 hours) |
Charging time | 2 hours |
Size | 240*75*57mm |
Weight | 570g |
To contact OBIAT Electronics Pty Ltd about CEM DT-9881 Air Particle Counter + Gas Detector use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.