FLIR Continuity, Voltage and Current Tester ...
The FLIR VT8’s optimized and open-jaw design allows it to fit into tight spaces and reliably measure large-diameter cables. Extensive measurement features make the FLIR VT8 a versatile tool – just one meter can get the job done. Carry the compact tester in your pocket to be ready at any moment for easy troubleshooting.
Choose from two models: the FLIR VT8-600 with a CAT III-600 V/CAT IV-300 V safety rating and a 100 A/600 V measuring range; or the FLIR VT8-1000 with the CAT III-1000 V/CAT IV-600 V safety rating and a 200 A/1000 V measuring range.
RUGGED AND SAFE
Made with the quality and reliability you have come to expect from FLIR test and measurement tools
RICH FEATURES
Equipped with the capabilities you need for one versatile troubleshooting tool
FLEXIBLE, EASY TO USE
Designed for long, trouble-free operation so you can focus on the task at hand
SPECIFICATIONS |
|
|
Part Number |
VT8-600 |
VT8-1000 |
Electrical Measurement |
|
|
True RMS Voltage and Current |
Yes |
|
Auto-Ranging |
Yes |
|
AC/DC Current Range |
100 A |
200 A |
AC/DC Current Resolution |
0.1 A |
|
AC (50 to 60 Hz) / DC Current Accuracy |
±2.5% |
|
AC/DC Voltage Range |
600 V |
1000 V |
AC/DC Voltage Resolution |
0.1 V |
|
AC (45 to 66 Hz) / DC Voltage Accuracy |
± 1.5%, ±1.0% |
|
Resistance |
60.00 MO ± (1.5%) |
|
Continuity Check Threshold |
10 O to 100 O |
|
Capacitance |
600 µF ±4.0%, 6000 µF ±10.0% |
|
Non-Contact Voltage Detector (NCV) |
=100 Vrms; =10 mm distance (LED/buzzer alerts) |
|
Additional Measurement Functions |
DCA zero, relative mode (AC/DC voltage, AC current, and capacitance), data hold |
|
General |
|
|
Worklights |
White LED |
|
Jaw Opening |
15.5 mm (0.61 in) |
|
Display |
6000-count backlit multi-function LCD |
|
Display Rate |
Approximately 3 times per second |
|
Polarity |
Automatic display of positive and negative polarity |
|
Over-Range Indication |
OL or "-OL" displayed |
|
Auto Power Off |
After 15 minutes |
|
Power Source |
2 x AA alkaline batteries |
|
Low battery Indication |
Battery symbol is displayed when batteries need changing |
|
Environmental Data |
|
|
Operating Temperature |
-10 to 50°C (14 to 122°F) |
|
Relative Humidity |
95% max; 5 to 30°C (41 to 86°F) / 75% max; 30 to 40°C (86 to 104°F) / 45% max; 40 to 50°C (104 to 122°F) |
|
Storage Temperature |
-30 to 60°C (-22 to 140°F), batteries not installed |
|
Drop Test |
2 m (6.6 ft) |
|
Physical Data |
|
|
Dimensions: (W × H × D) |
210 mm × 53 mm × 35 mm (8.27 in × 2.1 in × 0.67 in) |
|
Weight |
163.7 g (5.7 oz) including batteries |
|
General Information |
|
|
Warranty |
Limited 3-year |
|
Certifications |
C-UL-US, CE, RCM |
|
Safety Category Rating |
CAT IV-300 V |
CAT IV-600 V |
|
EN 61010-1 |
To contact Teledyne FLIR about FLIR Continuity, Voltage and Current Tester | VT8 use Get a quote.
The FLIR VT8’s optimized and open-jaw design allows it to fit into tight spaces and reliably measure large-diameter cables. Extensive measurement features make the FLIR VT8 a versatile tool – just one meter can get the job done. Carry the compact tester in your pocket to be ready at any moment for easy troubleshooting.
Choose from two models: the FLIR VT8-600 with a CAT III-600 V/CAT IV-300 V safety rating and a 100 A/600 V measuring range; or the FLIR VT8-1000 with the CAT III-1000 V/CAT IV-600 V safety rating and a 200 A/1000 V measuring range.
RUGGED AND SAFE
Made with the quality and reliability you have come to expect from FLIR test and measurement tools
RICH FEATURES
Equipped with the capabilities you need for one versatile troubleshooting tool
FLEXIBLE, EASY TO USE
Designed for long, trouble-free operation so you can focus on the task at hand
SPECIFICATIONS |
|
|
Part Number |
VT8-600 |
VT8-1000 |
Electrical Measurement |
|
|
True RMS Voltage and Current |
Yes |
|
Auto-Ranging |
Yes |
|
AC/DC Current Range |
100 A |
200 A |
AC/DC Current Resolution |
0.1 A |
|
AC (50 to 60 Hz) / DC Current Accuracy |
±2.5% |
|
AC/DC Voltage Range |
600 V |
1000 V |
AC/DC Voltage Resolution |
0.1 V |
|
AC (45 to 66 Hz) / DC Voltage Accuracy |
± 1.5%, ±1.0% |
|
Resistance |
60.00 MO ± (1.5%) |
|
Continuity Check Threshold |
10 O to 100 O |
|
Capacitance |
600 µF ±4.0%, 6000 µF ±10.0% |
|
Non-Contact Voltage Detector (NCV) |
=100 Vrms; =10 mm distance (LED/buzzer alerts) |
|
Additional Measurement Functions |
DCA zero, relative mode (AC/DC voltage, AC current, and capacitance), data hold |
|
General |
|
|
Worklights |
White LED |
|
Jaw Opening |
15.5 mm (0.61 in) |
|
Display |
6000-count backlit multi-function LCD |
|
Display Rate |
Approximately 3 times per second |
|
Polarity |
Automatic display of positive and negative polarity |
|
Over-Range Indication |
OL or "-OL" displayed |
|
Auto Power Off |
After 15 minutes |
|
Power Source |
2 x AA alkaline batteries |
|
Low battery Indication |
Battery symbol is displayed when batteries need changing |
|
Environmental Data |
|
|
Operating Temperature |
-10 to 50°C (14 to 122°F) |
|
Relative Humidity |
95% max; 5 to 30°C (41 to 86°F) / 75% max; 30 to 40°C (86 to 104°F) / 45% max; 40 to 50°C (104 to 122°F) |
|
Storage Temperature |
-30 to 60°C (-22 to 140°F), batteries not installed |
|
Drop Test |
2 m (6.6 ft) |
|
Physical Data |
|
|
Dimensions: (W × H × D) |
210 mm × 53 mm × 35 mm (8.27 in × 2.1 in × 0.67 in) |
|
Weight |
163.7 g (5.7 oz) including batteries |
|
General Information |
|
|
Warranty |
Limited 3-year |
|
Certifications |
C-UL-US, CE, RCM |
|
Safety Category Rating |
CAT IV-300 V |
CAT IV-600 V |
|
EN 61010-1 |
To contact Teledyne FLIR about FLIR Continuity, Voltage and Current Tester | VT8 use Get a quote.