Wika Pressure Sensor | IO-Link Compact ...
Applications for this product
Features of this product
The model DSSA11SA compact diaphragm seal system is particularly well suited for hygienic process integration in sanitary applications. The model DSSA11SA meets the requirements of CIP (Cleaning in Place) and SIP (Sterilization in Place) and withstands the temperatures of the cleaning steam.
The clamp connection (TRI-CLAMP®) enables quick and easy dismounting and thus a simple cleaning with seal replacement. In the basic version, the instrument is fitted with a pressure sensor without a display, which, depending on the application, can be used either for pressure monitoring or as an electronic PNP/NPN switch for process control.
With an additional IO-Link interface, the instrument can be programmed flexibly and has integrated diagnostic functions that monitor the instrument's status. In addition, this allows the digital signal to be configured externally and conveniently at any time. This version, which has been enhanced with a 360° LED status indication, provides visual information about the status and enables intuitive and quick error detection and correction. For maintenance, a blinking function via IO-Link facilitates the clear localization of a diaphragm seal system. The blinking function prevents confusion of measuring locations and accelerates maintenance.
Specifications of this product
Accuracy, switching output 1) ¦ ≤ ±1 % of span or ¦ ≤ ±0.5 % of span
Zero point setting Max. 3 % of span (via IO-Link)
Temperature error 2) ≤ ±1.5 % of span ≤ ±2.5 % of span for increased overload safety
Mean temperature coefficient 2) Zero point ≤ ±0.16 % of span/10 K Span ≤ ±0.16 % of span/10 K
Reference conditions per IEC 61298-1
Ambient temperature 23 °C ±2 °C [73 °F ±7 °F]
Atmospheric pressure 860 ... 1,060 mbar [86 ... 106 kPa, 12.5 ... 15.4 psi]
Air humidity 45 ... 75 % r. h.
Mounting position Vertical, diaphragm points downward
Supply voltage DC 10…32 V
1) Including non-linearity, hysteresis, zero offset and end value deviation (corresponds to measured error per IEC 61298-2). 2) Valid for the medium and ambient temperature ranges specified on page 8 and DN 1 ½" process connection in accordance with the DIN 11866 row C pipe standard or ASME BP
Pressure ranges from 0...1 bar up to 0...40 bar, including compound and vacuum ranges.
Latest IO-Link specification: Version 1.1
To contact WIKA Australia about Wika Pressure Sensor | IO-Link Compact Hygienic Design use Get a quote.
Applications for this product
Features of this product
The model DSSA11SA compact diaphragm seal system is particularly well suited for hygienic process integration in sanitary applications. The model DSSA11SA meets the requirements of CIP (Cleaning in Place) and SIP (Sterilization in Place) and withstands the temperatures of the cleaning steam.
The clamp connection (TRI-CLAMP®) enables quick and easy dismounting and thus a simple cleaning with seal replacement. In the basic version, the instrument is fitted with a pressure sensor without a display, which, depending on the application, can be used either for pressure monitoring or as an electronic PNP/NPN switch for process control.
With an additional IO-Link interface, the instrument can be programmed flexibly and has integrated diagnostic functions that monitor the instrument's status. In addition, this allows the digital signal to be configured externally and conveniently at any time. This version, which has been enhanced with a 360° LED status indication, provides visual information about the status and enables intuitive and quick error detection and correction. For maintenance, a blinking function via IO-Link facilitates the clear localization of a diaphragm seal system. The blinking function prevents confusion of measuring locations and accelerates maintenance.
Specifications of this product
Accuracy, switching output 1) ¦ ≤ ±1 % of span or ¦ ≤ ±0.5 % of span
Zero point setting Max. 3 % of span (via IO-Link)
Temperature error 2) ≤ ±1.5 % of span ≤ ±2.5 % of span for increased overload safety
Mean temperature coefficient 2) Zero point ≤ ±0.16 % of span/10 K Span ≤ ±0.16 % of span/10 K
Reference conditions per IEC 61298-1
Ambient temperature 23 °C ±2 °C [73 °F ±7 °F]
Atmospheric pressure 860 ... 1,060 mbar [86 ... 106 kPa, 12.5 ... 15.4 psi]
Air humidity 45 ... 75 % r. h.
Mounting position Vertical, diaphragm points downward
Supply voltage DC 10…32 V
1) Including non-linearity, hysteresis, zero offset and end value deviation (corresponds to measured error per IEC 61298-2). 2) Valid for the medium and ambient temperature ranges specified on page 8 and DN 1 ½" process connection in accordance with the DIN 11866 row C pipe standard or ASME BP
Pressure ranges from 0...1 bar up to 0...40 bar, including compound and vacuum ranges.
Latest IO-Link specification: Version 1.1
To contact WIKA Australia about Wika Pressure Sensor | IO-Link Compact Hygienic Design use Get a quote.