Softing Modbus Gateway | OPC UA Gateway ...
Supported dataFEED Features | OPC UA Server and Client, OPC Classic Server and Client, OPC Tunnel, MQTT and REST Connector, Database Access (SQL/NoSQL), File Access, Data Exchange (in any direction between OPC UA and OPC Classic Servers or controllers), Filter, Optimizer, Concentrator, Bridge, Local Items (in any direction between OPC UA and OPC Classic Clients) |
Supported Controllers | Siemens S5, S7 (200,300,400,1200,1500 including optimized blocks), LOGO! 8, PAC Counter and Siemens-compatible controllers like VIPA controllers Rockwell SLC-500, PLC-5, ControlLogix and CompactLogix Mitsubishi Melsec-Q Series with Ethernet interface card B&R controllers with Ethernet interface Modbus TCP-compatible controllers (Wago, Beckhoff, Phoenix, Schneider, etc.) All controllers and devices with integrated OPC UA Server |
Accessible Controller Data | Inputs, outputs, data blocks, markers, timers, counters |
Supported OPC Specifications | OPC Classic Data Access V1.0a, V2.05, V3.0, OPC Classic XML-DA V1.01, OPC Alarms & Events V1.10, OPC Unified Architecture V1.02 |
Supported OPC UAFunctionality |
Data Access profile TCP transport protocol using OPC UA binary coding Security Methods: Basic256SSha256, Basic256, Basic128Rsa15, None Authentication by user names and passwords including user certificate |
Supported OPC Data Types | VARIANT Data Types I1, UI1, I2, UI2, I4, UI4, R4, DATE, BSTR, BOOL and arrays (VT_Array) of these data types |
Protocols for IoT Cloud Link |
MQTT Publisher REST Client |
Supported Databases | NoSQL databases, e.g. MongoDB, CouchDB ODBC enabled databases, for example, Oracle, MySQL, Microsoft SQL Server, IBM DB2, other NoSQL- and ODBC-enabled databases upon inquiry |
Operation Mode | Application (OutProc Server), Windows Service |
Logging, Diagnostics | Logging of OPC Calls and Notifications, OPC Data, OPC Tunnel frames, text file access, database access, configurable via integrated web server diagnostic interface |
Supported Operating Systems | Windows 7, Windows 8, Windows 8.1, Windows Embedded 8.1 Industry, Windows 10 Windows Server 2003, Windows Server 2008, Windows Server 2008 R2, Windows Server 2012,Windows Server 2012 R2, Windows Server 2016 |
Licensing | Runtime license per computer |
Demo Version | Full dataFEED OPC Suite, time limited to 72 hours |
To contact Ti2 Pty Ltd about Softing Modbus Gateway | OPC UA Gateway for Siemens and MODBUS PLCs - edgeGate use Get a quote.
Supported dataFEED Features | OPC UA Server and Client, OPC Classic Server and Client, OPC Tunnel, MQTT and REST Connector, Database Access (SQL/NoSQL), File Access, Data Exchange (in any direction between OPC UA and OPC Classic Servers or controllers), Filter, Optimizer, Concentrator, Bridge, Local Items (in any direction between OPC UA and OPC Classic Clients) |
Supported Controllers | Siemens S5, S7 (200,300,400,1200,1500 including optimized blocks), LOGO! 8, PAC Counter and Siemens-compatible controllers like VIPA controllers Rockwell SLC-500, PLC-5, ControlLogix and CompactLogix Mitsubishi Melsec-Q Series with Ethernet interface card B&R controllers with Ethernet interface Modbus TCP-compatible controllers (Wago, Beckhoff, Phoenix, Schneider, etc.) All controllers and devices with integrated OPC UA Server |
Accessible Controller Data | Inputs, outputs, data blocks, markers, timers, counters |
Supported OPC Specifications | OPC Classic Data Access V1.0a, V2.05, V3.0, OPC Classic XML-DA V1.01, OPC Alarms & Events V1.10, OPC Unified Architecture V1.02 |
Supported OPC UAFunctionality |
Data Access profile TCP transport protocol using OPC UA binary coding Security Methods: Basic256SSha256, Basic256, Basic128Rsa15, None Authentication by user names and passwords including user certificate |
Supported OPC Data Types | VARIANT Data Types I1, UI1, I2, UI2, I4, UI4, R4, DATE, BSTR, BOOL and arrays (VT_Array) of these data types |
Protocols for IoT Cloud Link |
MQTT Publisher REST Client |
Supported Databases | NoSQL databases, e.g. MongoDB, CouchDB ODBC enabled databases, for example, Oracle, MySQL, Microsoft SQL Server, IBM DB2, other NoSQL- and ODBC-enabled databases upon inquiry |
Operation Mode | Application (OutProc Server), Windows Service |
Logging, Diagnostics | Logging of OPC Calls and Notifications, OPC Data, OPC Tunnel frames, text file access, database access, configurable via integrated web server diagnostic interface |
Supported Operating Systems | Windows 7, Windows 8, Windows 8.1, Windows Embedded 8.1 Industry, Windows 10 Windows Server 2003, Windows Server 2008, Windows Server 2008 R2, Windows Server 2012,Windows Server 2012 R2, Windows Server 2016 |
Licensing | Runtime license per computer |
Demo Version | Full dataFEED OPC Suite, time limited to 72 hours |
To contact Ti2 Pty Ltd about Softing Modbus Gateway | OPC UA Gateway for Siemens and MODBUS PLCs - edgeGate use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product