VAV Terminal Control Units Type TFP
Considerable operating savings can be achieved through the recovery of waste heat,reduced central fan horsepower requirements and night setback operation. TROX Tennlnal Boxes Type ''TFP" take primary and induced air and mix the two thoroughly to provide a constant air supply to the occupied zone of the building.Totalflow to the diffuser Is kept substantially constant thus giving very good air distribution even with high turn down of the primary air volume.
A pressure independent control of the primary VAV damper is accomplished by use of a differential pressure grid which gives accurate control of air flow even with a goo bend on the inlet spigot.Mixing between the primary airstr8am and the induced warm air from the ceiling void is by a forward curved blade centrifugal fan with direct drive motor.
TROX Series Fan Tenninal Boxes are eminently suitable for low temperature air applications.If the supply air temperature is low,then the fan volume flow rate must be higher than the primary air volume flow rate to ensure suitable air temperature at the diffuser.The design of the type TFP ensures that at 100 % primary air,sulftclent Induced air Is mixed with the primary air so that the air discharged has a conventional cooling differential which will not cause draught problems In the space being conditioned.The primary air damper can also be fully shut,with 100 % recirculated or induced air.
To contact TROX Australia about VAV Terminal Control Units Type TFP use Get a quote.
Considerable operating savings can be achieved through the recovery of waste heat,reduced central fan horsepower requirements and night setback operation. TROX Tennlnal Boxes Type ''TFP" take primary and induced air and mix the two thoroughly to provide a constant air supply to the occupied zone of the building.Totalflow to the diffuser Is kept substantially constant thus giving very good air distribution even with high turn down of the primary air volume.
A pressure independent control of the primary VAV damper is accomplished by use of a differential pressure grid which gives accurate control of air flow even with a goo bend on the inlet spigot.Mixing between the primary airstr8am and the induced warm air from the ceiling void is by a forward curved blade centrifugal fan with direct drive motor.
TROX Series Fan Tenninal Boxes are eminently suitable for low temperature air applications.If the supply air temperature is low,then the fan volume flow rate must be higher than the primary air volume flow rate to ensure suitable air temperature at the diffuser.The design of the type TFP ensures that at 100 % primary air,sulftclent Induced air Is mixed with the primary air so that the air discharged has a conventional cooling differential which will not cause draught problems In the space being conditioned.The primary air damper can also be fully shut,with 100 % recirculated or induced air.
To contact TROX Australia about VAV Terminal Control Units Type TFP use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product