AC Drives and Motors|Unidrive SP Panel ...
The drives are easy to install and commission and can be applied in a wide range of applications. Unidrive SP can be configured to operate in the following modes:
Servo for synchronous permanent magnet motors / brushless servo motors
Features
Widest range of system integration feature
Unidrive SP offers the widest range of system integration features, each drive can accept three option modules, allowing you to select the level of integrated automation / motion control, connectivity and I/O that you need. Click on the options tab for more information.
High performance motor control
Unidrive SP is applied in the most demanding applications, where dynamic, high performance motor control is required, from precision automotive test stands to high speed manufacturing machinery.
Back-up power supplies for continuous operation
Back-up power supplies ensure the drives are always ready for action, eliminating start-up routines and providing safety back-up for critical equipment.
Flexible power systems - lower harmonics
In applications where there is a significant amount of stored mechanical energy, the drive must be able to transfer the energy from the mechanical system to control the motor speed. Unidrive SP can be used to return excess energy to a shared DC bus or to the AC supply. Benefits include:
On-Board PLC
Unidrive SP has an inbuilt programmable controller. It is configured using an easy-to-use ladder logic program editor, suitable for replacing relay logic or a micro PLC for simple drive control applications.
Easy Parameter Back-up and Copy
The Smartcard is a memory device that is supplied with every Unidrive SP, it can be used to back-up parameter sets and PLC programs and copy them from one drive to another.
Integrated brake resistors
Unidrive SP frame sizes 0 to 2 feature an optional heatsink mounted brake resistor. This arrangement simplifies installation and requires no additional space.
Flexible mounting
Unidrive SP panel mount drives can be surface mounted or the heatsink through panel mounted, allowing the heat to be dissipated externally. This reduces the temperature rise inside the control panel. An IP54 (NEMA 12) mounting kit is included with the drive as standard and IP54 (NEMA 12) versions of the heatsink fan are available as an option. This mounting method allows smaller enclosure dimensions and reduces the need for ventilation.
Safety as standard
Unidrive SP’s Safe Torque Off (STO) is a functional safety feature which complies with EN/IEC 61800-5-2 SIL 3 and is built in to the drive as standard. When the Safe Torque Off function is active, the drive output is disabled with a high degree of integrity.
Safe Torque Off can form part of an EN 954-1 Category 4 system by adding additional control circuitry.
To contact Nidec Industrial Automation Australia (Control Techniques) about AC Drives and Motors|Unidrive SP Panel Mount use Get a quote.
The drives are easy to install and commission and can be applied in a wide range of applications. Unidrive SP can be configured to operate in the following modes:
Servo for synchronous permanent magnet motors / brushless servo motors
Features
Widest range of system integration feature
Unidrive SP offers the widest range of system integration features, each drive can accept three option modules, allowing you to select the level of integrated automation / motion control, connectivity and I/O that you need. Click on the options tab for more information.
High performance motor control
Unidrive SP is applied in the most demanding applications, where dynamic, high performance motor control is required, from precision automotive test stands to high speed manufacturing machinery.
Back-up power supplies for continuous operation
Back-up power supplies ensure the drives are always ready for action, eliminating start-up routines and providing safety back-up for critical equipment.
Flexible power systems - lower harmonics
In applications where there is a significant amount of stored mechanical energy, the drive must be able to transfer the energy from the mechanical system to control the motor speed. Unidrive SP can be used to return excess energy to a shared DC bus or to the AC supply. Benefits include:
On-Board PLC
Unidrive SP has an inbuilt programmable controller. It is configured using an easy-to-use ladder logic program editor, suitable for replacing relay logic or a micro PLC for simple drive control applications.
Easy Parameter Back-up and Copy
The Smartcard is a memory device that is supplied with every Unidrive SP, it can be used to back-up parameter sets and PLC programs and copy them from one drive to another.
Integrated brake resistors
Unidrive SP frame sizes 0 to 2 feature an optional heatsink mounted brake resistor. This arrangement simplifies installation and requires no additional space.
Flexible mounting
Unidrive SP panel mount drives can be surface mounted or the heatsink through panel mounted, allowing the heat to be dissipated externally. This reduces the temperature rise inside the control panel. An IP54 (NEMA 12) mounting kit is included with the drive as standard and IP54 (NEMA 12) versions of the heatsink fan are available as an option. This mounting method allows smaller enclosure dimensions and reduces the need for ventilation.
Safety as standard
Unidrive SP’s Safe Torque Off (STO) is a functional safety feature which complies with EN/IEC 61800-5-2 SIL 3 and is built in to the drive as standard. When the Safe Torque Off function is active, the drive output is disabled with a high degree of integrity.
Safe Torque Off can form part of an EN 954-1 Category 4 system by adding additional control circuitry.
To contact Nidec Industrial Automation Australia (Control Techniques) about AC Drives and Motors|Unidrive SP Panel Mount use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product