The PT110LC, PT111LC and PT112LC are DIN rail mounted micro-controller based analogue load cell transmitters.
Description
38 Recent ViewsCall for more details
The Azure Signature Series Analogue Load Cell Conditioners are very high accuracy and long term stability with advanced design.
Using an up to-date delta-sigma ADC and 16 bit DAC to achieve higher speed and accuracy these instruments give the system designers a lot of advantages towards increasing system reliability and reducing the installation and service times. All instruments’ analogue outputs are matched during production to simplify calibration with a PLC and to simplify exchanging the instrument without recalibration in service when initial adjustment has been performed in the PLC.
There are 8 position rotary switches and annunciator LEDs on the front panel of the instruments. The upper rotary switch adjusts the empty scale’s analogue output level (zero adjustment) and the lower rotary switch adjusts the gain of the instrument (span).
Additionally the PT111LC has 2 set point relay outputs for process control or alarms, more analogue output options and and an RS232 port for configuration via PC and AzCom
The PT112LC is a high speed version of the PT111LC.
Azure Signature Series Analogue Load Cell Conditioners Features
Minimized zero and span drifts due to use of micro-controller technology.
High accuracy, very low temperature drift 24 bit ADC and 16 bit DAC converters.
Compact DIN rail mounting, size is only 22.5mm × 99mm from the front.
Long term stability and low temperature drifts eliminate the need for frequent readjustment.
Digital adaptive anti-vibration filter to minimize errors from environmental vibrations.
All instrument have been pre-calibrated to 0–10 V and to 4–20 mA analog output ranges for 0–2mV/V load cell signal range as a factory default.
Factory matching facilitates swap out without PLC readjustment.
Intergration
Inputs most strain gauge bridge devices (load and pressure).
Analogue output, selectable 0-10V or 4-20mA.
PT111LC features extra to PT110LC
Additional output options 0-5V, 0-20mA.
2 set point relay outputs.
Programmable via PC, PLC and AzCom software.
Calibration without calibration weights (using load cell mV/V entry).
PT112LC features extra to PT111LC
High speed conversion and response for fast changing processes.
For more information or a qoute please call or email for a direct reply.
To contact PT Limited about Analogue Load Cell Conditioner | Azure Signature Series use Get a quote.
The Azure Signature Series Analogue Load Cell Conditioners are very high accuracy and long term stability with advanced design.
Using an up to-date delta-sigma ADC and 16 bit DAC to achieve higher speed and accuracy these instruments give the system designers a lot of advantages towards increasing system reliability and reducing the installation and service times. All instruments’ analogue outputs are matched during production to simplify calibration with a PLC and to simplify exchanging the instrument without recalibration in service when initial adjustment has been performed in the PLC.
There are 8 position rotary switches and annunciator LEDs on the front panel of the instruments. The upper rotary switch adjusts the empty scale’s analogue output level (zero adjustment) and the lower rotary switch adjusts the gain of the instrument (span).
Additionally the PT111LC has 2 set point relay outputs for process control or alarms, more analogue output options and and an RS232 port for configuration via PC and AzCom
The PT112LC is a high speed version of the PT111LC.
Azure Signature Series Analogue Load Cell Conditioners Features
Minimized zero and span drifts due to use of micro-controller technology.
High accuracy, very low temperature drift 24 bit ADC and 16 bit DAC converters.
Compact DIN rail mounting, size is only 22.5mm × 99mm from the front.
Long term stability and low temperature drifts eliminate the need for frequent readjustment.
Digital adaptive anti-vibration filter to minimize errors from environmental vibrations.
All instrument have been pre-calibrated to 0–10 V and to 4–20 mA analog output ranges for 0–2mV/V load cell signal range as a factory default.
Factory matching facilitates swap out without PLC readjustment.
Intergration
Inputs most strain gauge bridge devices (load and pressure).
Analogue output, selectable 0-10V or 4-20mA.
PT111LC features extra to PT110LC
Additional output options 0-5V, 0-20mA.
2 set point relay outputs.
Programmable via PC, PLC and AzCom software.
Calibration without calibration weights (using load cell mV/V entry).
PT112LC features extra to PT111LC
High speed conversion and response for fast changing processes.
For more information or a qoute please call or email for a direct reply.