Measurement Clamp on Current Probe - P50 ...
The P50 Measurement Clamp is a general purpose 1000A AC current probe designed for use with DMMs, loggers and other instruments that have a current input. It has a 1000:1 ratio and output of 1mA per amp or 1mV per amp measured in the jaw. The P50 has an integral 2.5m lead terminated. The rounded jaw design on this probe makes it well-suited for power applications where high accuracy 0.1% and low phase shift and wide frequency response are important.
Applications
Features
Parameters
Electrical parameters | |||||||
---|---|---|---|---|---|---|---|
Ratio | 1000: 1 or 2000:1 (customized) | ||||||
Accuracy class | 0.1%, 0.2%, 0.5% | ||||||
Primary current | 0 - 1000A AC | ||||||
Secondary current | 1mV/A AC, 5mV/A or (customized) | ||||||
Max. Cont. Input current | 1200A | ||||||
Over voltage category | CAT III 600V | ||||||
Output signal (AC current) | 333mV, 500mV,1V,2V,5V AC at nominal input current | ||||||
AC Accuracy(1000A Range) | |||||||
0-10A | 0.5% | ||||||
10-100 | 0.2% | ||||||
10-1200A | 0.1% | ||||||
AC Phase Shift(1000A Range) | |||||||
0-10A | 0.5 degree | ||||||
10-100 | 0.2 degree | ||||||
10-1200A | 0.1 degree | ||||||
Frequency range | 40Hz-2000Hz | ||||||
Dielectric strength | 3KV 50Hz/60Hz at 1 minute | ||||||
Temperature range | -20 C to +55 C | ||||||
Output | 2.5 meter cable with D01 connector | ||||||
Max. voltage not insulated conductors | 600 V | ||||||
Standard | EN 61010-1, EN 61010-2-032, IEC60044-1 | ||||||
Installation | Clamp type | ||||||
Output mode | Lead output (2.5m) | ||||||
Mechanical parameters | |||||||
Dimensions (L x W x H)(mm) | 102.9 x 219.6 x 28 | ||||||
Weight (g) | 550 | ||||||
Holding wire diameter (mm) | 50 | ||||||
Max. jaw opening (mm) | 50 | ||||||
Color | Gray or blue | ||||||
Material | PC+ABS+Polycarbonate, UL94 V0 |
To contact Beijing GFUVE Electronics Co.,Ltd. about Measurement Clamp on Current Probe - P50 1000A use Get a quote.
The P50 Measurement Clamp is a general purpose 1000A AC current probe designed for use with DMMs, loggers and other instruments that have a current input. It has a 1000:1 ratio and output of 1mA per amp or 1mV per amp measured in the jaw. The P50 has an integral 2.5m lead terminated. The rounded jaw design on this probe makes it well-suited for power applications where high accuracy 0.1% and low phase shift and wide frequency response are important.
Applications
Features
Parameters
Electrical parameters | |||||||
---|---|---|---|---|---|---|---|
Ratio | 1000: 1 or 2000:1 (customized) | ||||||
Accuracy class | 0.1%, 0.2%, 0.5% | ||||||
Primary current | 0 - 1000A AC | ||||||
Secondary current | 1mV/A AC, 5mV/A or (customized) | ||||||
Max. Cont. Input current | 1200A | ||||||
Over voltage category | CAT III 600V | ||||||
Output signal (AC current) | 333mV, 500mV,1V,2V,5V AC at nominal input current | ||||||
AC Accuracy(1000A Range) | |||||||
0-10A | 0.5% | ||||||
10-100 | 0.2% | ||||||
10-1200A | 0.1% | ||||||
AC Phase Shift(1000A Range) | |||||||
0-10A | 0.5 degree | ||||||
10-100 | 0.2 degree | ||||||
10-1200A | 0.1 degree | ||||||
Frequency range | 40Hz-2000Hz | ||||||
Dielectric strength | 3KV 50Hz/60Hz at 1 minute | ||||||
Temperature range | -20 C to +55 C | ||||||
Output | 2.5 meter cable with D01 connector | ||||||
Max. voltage not insulated conductors | 600 V | ||||||
Standard | EN 61010-1, EN 61010-2-032, IEC60044-1 | ||||||
Installation | Clamp type | ||||||
Output mode | Lead output (2.5m) | ||||||
Mechanical parameters | |||||||
Dimensions (L x W x H)(mm) | 102.9 x 219.6 x 28 | ||||||
Weight (g) | 550 | ||||||
Holding wire diameter (mm) | 50 | ||||||
Max. jaw opening (mm) | 50 | ||||||
Color | Gray or blue | ||||||
Material | PC+ABS+Polycarbonate, UL94 V0 |
To contact Beijing GFUVE Electronics Co.,Ltd. about Measurement Clamp on Current Probe - P50 1000A use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product