Turtle Tough Dissolved Oxygen Analyzer | ...
The unique modular design enables you to create a fully functional, multi-parameter analyser with any combination of different TT-MA analytical modules.
The TT-MA-DO Analyser Module has been designed specifically to support the high performance features of our world leading sensors. Don't be fooled by the compact size as these little modules are a fully capable analyser. The ability to plug an play a variety of expansion modules creates a powerful array of analysing hardware.
The TT-MA-DO analyser module displays and outputs the concentration of dissolved oxygen in ppm, % saturation units, as well as the process temperature. Automatic correction for temperature, pressure and salinity for calibration and % saturation measurement modes.
A simple gain calibration procedure is performed with the sensor dry in air. The convenient automatic or manual mode gain calibration allows adjustment of the sensor slope (mV per ppm DO) to the correct value based upon pre-programmed 100% DO saturation at that temperature & pressure.
No look-up tables are ever needed to calibrate the dissolved oxygen sensor in the field. No “Zero” calibration is ever needed as our sensors have a true zero potential.
Key Features:
To contact Turtle Tough about Turtle Tough Dissolved Oxygen Analyzer | TT-MA-DO use Get a quote.
The unique modular design enables you to create a fully functional, multi-parameter analyser with any combination of different TT-MA analytical modules.
The TT-MA-DO Analyser Module has been designed specifically to support the high performance features of our world leading sensors. Don't be fooled by the compact size as these little modules are a fully capable analyser. The ability to plug an play a variety of expansion modules creates a powerful array of analysing hardware.
The TT-MA-DO analyser module displays and outputs the concentration of dissolved oxygen in ppm, % saturation units, as well as the process temperature. Automatic correction for temperature, pressure and salinity for calibration and % saturation measurement modes.
A simple gain calibration procedure is performed with the sensor dry in air. The convenient automatic or manual mode gain calibration allows adjustment of the sensor slope (mV per ppm DO) to the correct value based upon pre-programmed 100% DO saturation at that temperature & pressure.
No look-up tables are ever needed to calibrate the dissolved oxygen sensor in the field. No “Zero” calibration is ever needed as our sensors have a true zero potential.
Key Features:
To contact Turtle Tough about Turtle Tough Dissolved Oxygen Analyzer | TT-MA-DO use Get a quote.