Diesel Generator | 165KVA, 3 Phase, with Engine | ED165JDS/3
Diesel Generator | 165KVA, 3 Phase, with Engine | ED165JDS/3
Diesel Generator | 165KVA, 3 Phase, with Engine | ED165JDS/3
Diesel Generator | 165KVA, 3 Phase, with Engine | ED165JDS/3
Diesel Generator | 165KVA, 3 Phase, with Engine | ED165JDS/3
The John Deere powered ED165JDS/3 is a 165kVA three phase diesel generator.
Description
Documents
In Stock
Complete with Crossley SLG series single bearing, 4-pole, brushless alternator, remote start/stop control system, 260 litre fuel tank and John Deere engine. Welling and Crossley John Deere powered diesel generators are fully integrated power generation system that are stringently tested to provide optimum performance, reliability, and versatility for both stationary and prime power applications. Weather protective acoustic canopy options available.
Product Features:
Heavy duty fabricated steel base frame The complete generating set is mounted as a whole onto a heavy duty fabricated steel base frame. Anti-vibration pads are fixed between the engine and alternator feet, and the base frame, ensuring complete vibration isolation of the rotating assembly.
Bunded Fuel Tank (AS 1940-2004 compliant) The fuel tank is fully bunded and complies fully with relevant sections in AS 1940-2004. It has a secondary containment compound with a capacity as big or bigger than that of the tank, and is made of surface coated steel. This compound is designed to sufficiently retain spillage and enable recovery of any spillage. For more information regarding AS 1940-2004 compliance refer to the standard, or contact us.
Battery Charger This trickle charge battery charger ensures that your generator can start up when needed. It has both 12v and 24v charging capabilities.
Control Panel with Emergency Stop button This control panel monitors the controls of a single unit to achieve automatic start/stop, data measuring/monitoring, alarm protection and three remote systems (remote control, remote measuring and remote communication). The controller adopts large liquid crystal display (LCD) and has a 32 bit micro-processor with precision parameters for measuring, fixed value adjustment, time setting and threshold adjustment.
Prime or Standby Power
Standby: kVA @ 0.8 pf These ratings are applicable for supplying continuous electrical power (at variable loads) in the event of a utility power failure. No overload is permitted on these ratings. Minimum output from alternators are peak continuous rated (as defined in 1SO 8528-3 @ 27°C. Annual hour limitation: 500 hours).
Prime (continuous): kVA @ 0.8 pf. (Divide standby rating by 1.1). Available for continuous electrical output. There is no hour limitation. 10% overload is available 1 hour in 12. The generating set and this specification is designed for environmental conditions of up to 27°C, up to 152.4 m above sea level and up to 60% relative humidity. Ratings at 0.8 pf.
Product Specifications:
Alternator
Alternator Model: Crossley SLG Series
Electric Power: Three Phase
Active Rating: 165 kVA at 0.8 pf (Standby)
Power: 132 kW
Electric Potential: 415V
Frequency: 50Hz
Engine
Engine Model: John Deere 6068H
Engine Speed: 1500 rpm
Cylinder No.: 6TI
Cubic Capacity: 6.8 L
Bore / Stroke: 106 x 127 mm
Compression Ratio: 17.2 : 1
Aspiration: Turbocharged
Starter Voltage: 12 V
Flywheel ( Max. Continuous Power): 148 kW
Combustion Air Flow: 17.6 m³/min
Cooling Air Flow: 260 m³/min
Cooling System: Radiator Cooled
Heat Rejection to Cooling System: 133 kW
Exhaust Gas Flow: 42.3 m³/min
Exhaust Gas Temperature: 533°C
Fuel Type: Diesel
Fuel Tank Capacity: 260 L
Approx. Fuel Consumption (Continuous): 34.8 L/hr
Approx. Fuel Consumption (Standby): 38 L/hr
Generator
Dimensions (L x W x H): 2845 x 1070 x 1650 mm (L x W x H)
To contact Welling & Crossley about Welling and Crossley Diesel Generator | 165KVA, 3 Phase, with Engine | ED165JDS/3 use Get a quote.
Complete with Crossley SLG series single bearing, 4-pole, brushless alternator, remote start/stop control system, 260 litre fuel tank and John Deere engine. Welling and Crossley John Deere powered diesel generators are fully integrated power generation system that are stringently tested to provide optimum performance, reliability, and versatility for both stationary and prime power applications. Weather protective acoustic canopy options available.
Product Features:
Heavy duty fabricated steel base frame The complete generating set is mounted as a whole onto a heavy duty fabricated steel base frame. Anti-vibration pads are fixed between the engine and alternator feet, and the base frame, ensuring complete vibration isolation of the rotating assembly.
Bunded Fuel Tank (AS 1940-2004 compliant) The fuel tank is fully bunded and complies fully with relevant sections in AS 1940-2004. It has a secondary containment compound with a capacity as big or bigger than that of the tank, and is made of surface coated steel. This compound is designed to sufficiently retain spillage and enable recovery of any spillage. For more information regarding AS 1940-2004 compliance refer to the standard, or contact us.
Battery Charger This trickle charge battery charger ensures that your generator can start up when needed. It has both 12v and 24v charging capabilities.
Control Panel with Emergency Stop button This control panel monitors the controls of a single unit to achieve automatic start/stop, data measuring/monitoring, alarm protection and three remote systems (remote control, remote measuring and remote communication). The controller adopts large liquid crystal display (LCD) and has a 32 bit micro-processor with precision parameters for measuring, fixed value adjustment, time setting and threshold adjustment.
Prime or Standby Power
Standby: kVA @ 0.8 pf These ratings are applicable for supplying continuous electrical power (at variable loads) in the event of a utility power failure. No overload is permitted on these ratings. Minimum output from alternators are peak continuous rated (as defined in 1SO 8528-3 @ 27°C. Annual hour limitation: 500 hours).
Prime (continuous): kVA @ 0.8 pf. (Divide standby rating by 1.1). Available for continuous electrical output. There is no hour limitation. 10% overload is available 1 hour in 12. The generating set and this specification is designed for environmental conditions of up to 27°C, up to 152.4 m above sea level and up to 60% relative humidity. Ratings at 0.8 pf.
Product Specifications:
Alternator
Alternator Model: Crossley SLG Series
Electric Power: Three Phase
Active Rating: 165 kVA at 0.8 pf (Standby)
Power: 132 kW
Electric Potential: 415V
Frequency: 50Hz
Engine
Engine Model: John Deere 6068H
Engine Speed: 1500 rpm
Cylinder No.: 6TI
Cubic Capacity: 6.8 L
Bore / Stroke: 106 x 127 mm
Compression Ratio: 17.2 : 1
Aspiration: Turbocharged
Starter Voltage: 12 V
Flywheel ( Max. Continuous Power): 148 kW
Combustion Air Flow: 17.6 m³/min
Cooling Air Flow: 260 m³/min
Cooling System: Radiator Cooled
Heat Rejection to Cooling System: 133 kW
Exhaust Gas Flow: 42.3 m³/min
Exhaust Gas Temperature: 533°C
Fuel Type: Diesel
Fuel Tank Capacity: 260 L
Approx. Fuel Consumption (Continuous): 34.8 L/hr
Approx. Fuel Consumption (Standby): 38 L/hr
Generator