TPE Watertube Steam Boilers
Watertube Steam Boilers
If you need large volumes of saturated or superheated steam, then the Thermal and Pressure Engineering watertube steam boilers are the best of breed. We can deliver these units from a 1.5 MW, right up to 35 MW.
Watertube steam boilers can be fired via conventional fuels (Diesel, LPG or Natural Gas). However, the ever increasing cost of fossil fuels, these steam boilers can be manufactured to take a large range of alternate fuels like coal, wood or even agricultural waste.
The Thermal and Pressure Engineering watertube steam boilers are of the “D Type” design which is well known for its efficiency and simplicity. This design utilises large radius tube bends and limits the required number of bends which reduces the stress on the tube and increases the unit life. All equipment is built to comply with Australian standards as well as being designed for ease of maintenance and repair.
Vertical Watertube Steam Boilers
Although the larger watertube steam boilers are manufactured as horizontal units, our small boilers are often asked for in vertical orientation. The vertical watertube steam boilers are convenient as they are easier to install in areas where space is limited. The vertical watertube steam boilers can be supplied in a variety of sizes from a small 50KW unit up to a maximum of around 1500KW.
Larger steam boilers available upon request.
Model | W150 | W200 | W300 | W400 | W500 | W600 |
---|---|---|---|---|---|---|
Capacity – MW | 1.5 | 2.0 | 3.0 | 4.0 | 5.0 | 6.0 |
Capacity – HP | 150 | 200 | 300 | 400 | 500 | 600 |
Evaporation KG/HR f & a 100C | 2300 | 3000 | 4600 | 6000 | 7500 | 9000 |
Heating Surface M² | 42 | 56 | 84 | 112 | 141 | 168 |
Fuel Usage Natural Gas M³/HR | 170 | 227 | 340 | 454 | 568 | 682 |
LPG LT/HR | 231 | 308 | 463 | 617 | 771 | 926 |
Diesel Oil LT/HR | 141 | 192 | 286 | 387 | 481 | 573 |
Main Steam Outlet (MM) | 65 | 80 | 80 | 100 | 150 | 150 |
Feedwater Inlet (MM) | 25 | 32 | 40 | 40 | 40 | 40 |
Safety Valve (MM) | 25 | 25 | 40 | 50 | 50 | 65 |
Blowdown Valve (MM) | 40 | 40 | 40 | 40 | 40 | 40 |
Flue Diameter (MM) | 350 | 400 | 450 | 500 | 600 | 700 |
Overall Height (MM) | 3750 | 3750 | 3750 | 3750 | 3750 | 3750 |
Overall Width (MM) | 2890 | 2890 | 2890 | 2890 | 2890 | 2890 |
Overall Length (MM) | 3100 | 3370 | 3500 | 3950 | 4900 | 6600 |
Weight – Dry (KG) | 6,800 | 9,000 | 11,500 | 13,800 | 15,800 | 16,400 |
Model | W800 | W1000 | W1200 | W1500 | W2000 | W2500 |
---|---|---|---|---|---|---|
Capacity – MW | 8 | 10 | 12 | 15 | 20 | 25 |
Capacity – HP | 800 | 1000 | 1200 | 1500 | 2000 | 2500 |
Evaporation KG/HR f & a 100C | 12500 | 15600 | 18700 | 23400 | 31300 | 40000 |
Standard Operating Pressure kpa | <1800 | <1800 | <1800 | <1800 | <1800 | <1800 |
Fuel Usage Natural Gas M³/HR | 886 | 1108 | 1329 | 1662 | 2216 | 2770 |
LPG LT/HR | 1348 | 1688 | 2025 | 2428 | 3237 | 4047 |
Diesel Oil LT/HR | 819 | 1023 | 1228 | 1535 | 2047 | 2559 |
Main Steam Outlet (MM) | 200 | 200 | 200 | 250 | 300 | 300 |
Feedwater Inlet (MM) | 50 | 50 | 50 | 65 | 65 | 65 |
Safety Valve (MM) | 2 x 65 | 2 x 65 | 3 x 65 | 3 x 65 | 3 x 65 | 3 x 65 |
Blowdown Valve (MM) | 50 | 50 | 50 | 50 | 50 | 50 |
Flue Diameter (MM) | 800 | 900 | 1000 | 1000 | 1200 | 1400 |
Overall Height (MM) | 4400 | 4400 | 4600 | 4600 | 4600 | 4600 |
Overall Width (MM) | 3400 | 3400 | 3400 | 4200 | 4200 | 4200 |
Overall Length (MM) | 6300 | 6500 | 7000 | 7000 | 8400 | 9400 |
Weight – Dry (KG) | 20,500 | 24,800 | 30,000 | 35,000 | 38,500 | 42,000 |
To contact Thermal & Pressure Engineering about TPE Watertube Steam Boilers use Get a quote.
Watertube Steam Boilers
If you need large volumes of saturated or superheated steam, then the Thermal and Pressure Engineering watertube steam boilers are the best of breed. We can deliver these units from a 1.5 MW, right up to 35 MW.
Watertube steam boilers can be fired via conventional fuels (Diesel, LPG or Natural Gas). However, the ever increasing cost of fossil fuels, these steam boilers can be manufactured to take a large range of alternate fuels like coal, wood or even agricultural waste.
The Thermal and Pressure Engineering watertube steam boilers are of the “D Type” design which is well known for its efficiency and simplicity. This design utilises large radius tube bends and limits the required number of bends which reduces the stress on the tube and increases the unit life. All equipment is built to comply with Australian standards as well as being designed for ease of maintenance and repair.
Vertical Watertube Steam Boilers
Although the larger watertube steam boilers are manufactured as horizontal units, our small boilers are often asked for in vertical orientation. The vertical watertube steam boilers are convenient as they are easier to install in areas where space is limited. The vertical watertube steam boilers can be supplied in a variety of sizes from a small 50KW unit up to a maximum of around 1500KW.
Larger steam boilers available upon request.
Model | W150 | W200 | W300 | W400 | W500 | W600 |
---|---|---|---|---|---|---|
Capacity – MW | 1.5 | 2.0 | 3.0 | 4.0 | 5.0 | 6.0 |
Capacity – HP | 150 | 200 | 300 | 400 | 500 | 600 |
Evaporation KG/HR f & a 100C | 2300 | 3000 | 4600 | 6000 | 7500 | 9000 |
Heating Surface M² | 42 | 56 | 84 | 112 | 141 | 168 |
Fuel Usage Natural Gas M³/HR | 170 | 227 | 340 | 454 | 568 | 682 |
LPG LT/HR | 231 | 308 | 463 | 617 | 771 | 926 |
Diesel Oil LT/HR | 141 | 192 | 286 | 387 | 481 | 573 |
Main Steam Outlet (MM) | 65 | 80 | 80 | 100 | 150 | 150 |
Feedwater Inlet (MM) | 25 | 32 | 40 | 40 | 40 | 40 |
Safety Valve (MM) | 25 | 25 | 40 | 50 | 50 | 65 |
Blowdown Valve (MM) | 40 | 40 | 40 | 40 | 40 | 40 |
Flue Diameter (MM) | 350 | 400 | 450 | 500 | 600 | 700 |
Overall Height (MM) | 3750 | 3750 | 3750 | 3750 | 3750 | 3750 |
Overall Width (MM) | 2890 | 2890 | 2890 | 2890 | 2890 | 2890 |
Overall Length (MM) | 3100 | 3370 | 3500 | 3950 | 4900 | 6600 |
Weight – Dry (KG) | 6,800 | 9,000 | 11,500 | 13,800 | 15,800 | 16,400 |
Model | W800 | W1000 | W1200 | W1500 | W2000 | W2500 |
---|---|---|---|---|---|---|
Capacity – MW | 8 | 10 | 12 | 15 | 20 | 25 |
Capacity – HP | 800 | 1000 | 1200 | 1500 | 2000 | 2500 |
Evaporation KG/HR f & a 100C | 12500 | 15600 | 18700 | 23400 | 31300 | 40000 |
Standard Operating Pressure kpa | <1800 | <1800 | <1800 | <1800 | <1800 | <1800 |
Fuel Usage Natural Gas M³/HR | 886 | 1108 | 1329 | 1662 | 2216 | 2770 |
LPG LT/HR | 1348 | 1688 | 2025 | 2428 | 3237 | 4047 |
Diesel Oil LT/HR | 819 | 1023 | 1228 | 1535 | 2047 | 2559 |
Main Steam Outlet (MM) | 200 | 200 | 200 | 250 | 300 | 300 |
Feedwater Inlet (MM) | 50 | 50 | 50 | 65 | 65 | 65 |
Safety Valve (MM) | 2 x 65 | 2 x 65 | 3 x 65 | 3 x 65 | 3 x 65 | 3 x 65 |
Blowdown Valve (MM) | 50 | 50 | 50 | 50 | 50 | 50 |
Flue Diameter (MM) | 800 | 900 | 1000 | 1000 | 1200 | 1400 |
Overall Height (MM) | 4400 | 4400 | 4600 | 4600 | 4600 | 4600 |
Overall Width (MM) | 3400 | 3400 | 3400 | 4200 | 4200 | 4200 |
Overall Length (MM) | 6300 | 6500 | 7000 | 7000 | 8400 | 9400 |
Weight – Dry (KG) | 20,500 | 24,800 | 30,000 | 35,000 | 38,500 | 42,000 |
To contact Thermal & Pressure Engineering about TPE Watertube Steam Boilers use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.